In Blog, Inverters, Micro Inverters & Optimisers, Solar for Beginners, Solar Panels

What size solar system do I need?

It’s one of the first questions you should ask when looking for solar: What size solar system should I get? This post will first dispel the “Goldilocks solar” myth of accurately sizing a solar system to match your daytime power consumption. I’ll then explain why for several years, a 5kW inverter with 6.6kW of panels had been our biggest seller. It sounds like one size fits all – right?
Next, I’ll explain how times are changing, and why in 2018, it is not uncommon that the best size solar system is just to cover the usable roof with solar panels.

Goldilocks solar

People often approach purchasing solar with Goldilocks wisdom. They know they don’t want a system that’s too small, and they don’t want to waste money on a system that’s too big.

I just want a solar system big enough to cover my daytime usage.

This seems reasonable. Why would you waste money on an oversized system that you won’t ever use?

The problem with attempting to size a system with the aim of covering daytime usage only – is that there are so many seasonal solar production and household consumption variables. If your system is too small in one situation, it will be too big in another situation. But let’s say you monitor your usage and you somehow find that a 3kW size solar system will closely match your usage patterns from sunrise to sunset, and from mid-winter to Chrismas day. Not too big and not too small. So you get onto Google and type “3kW Goldilocks Solar System”. The first thing that comes up is this blog “what size solar system do I need?” (because I just coined the term.)

Our pricing page shows an indicative price:
(Prices current January 2019)

  3kW Goldilocks Solar

Fronius Primo 3kW inverter (Austrian Made)

9 x 325W QCells (Korean made)

$5400  

Yes, that’s expensive! At that price, the Goldilocks solar system is starting to look like a fairy tale. You shouldn’t be surprised to learn, for that price, we hardly ever sell a 3kW system. But if you want a quality inverter, quality panels, and quality rail, isolators, fasteners, cables, sealants etc – and all installed by quality tradesmen – that’s just how much it costs.

But there is a better option.

What is the most common size solar system?

Over the last few years, our most popular solar system as listed on our pricing page has been this:
(Prices current May 2018)

Qcell Panels Systems

 6.6kW Solar

Fronius Primo 5kW inverter (Austrian Made)

22 x 300W QCells (Korean made)

$7400

While a 3kW size solar system is going to set you back $5400, a 6.6kW system will cost you $7400.

That’s only $2000 for the additional 3.6kW.  You’ll generate 120% of the power for just 38% more cost.

Why is a 3kW system so expensive?

Don’t get me wrong, we could sell you an entry-level Solar system for $4200. Or you could pick up some nasty roof bling, AKA “solar land-fill” with a drive-away warranty for under $3000.
I’m comparing a good quality 3kW system to a good quality 6.6kW system. But why isn’t the 3kW size solar system around half the price of a 6.6kW system?

  • A 3kW Fronius inverter only costs about $200 less than a 5kW, because it’s essentially the same as a 5kW inverter with different programming and a different compliance stamp. It’s about economies of scale. Most inverter manufacturers do the same.
  • Every panel we install attracts a “rebate” (technically called an STC) so the more panels you put on, the bigger the “rebate” you get. At today’s rate, a 3kW size solar system will attract a $1910 “rebate” where a 6kW system will attract a $4250 “rebate”. (This is a point of sale discount so it is already factored into the system prices above.)
  • Installing a 3kW size solar system may take 6 hours for a team, installing a 6.6kW system may only take 8 hours. (All of the switchboard work and the cable run between the inverter and the panels has to be done either way).

So the only real cost of installing the larger system is 11 extra panels (that are largely paid for by the STC “rebate”), extra rail to mount panels on, a few hundred bucks for a 5kW inverter, and a couple of extra hours labour for the blokes on the roof.

But do I need a 6.6kw solar system?

My home will not use the power generated from a 6.6kW system. So why wouldn’t I just keep the extra 2 grand in my pocket.

When the feed-in tariff was as low as 6 cents, there wasn’t much incentive to feed power back to the grid. But with feed-in tariffs now between 10 and 14 cents (and likely to rise as power prices rise) feeding power back to the grid makes more sense. Especially when you only spend an additional $2000 for more than twice the size solar system. The figures look something like this:

  • The additional 3.3kW of solar produces about 5000kWh a year
  • Assume you send all of that back to the grid. (However on rainy days, early mornings and winter months you will use that extra generation.)
  • 5000kWh @ 14 cent (feed-in tariff) = $700 a year
  • You will see a return on your $2000 in less than 3 years

You may be wondering why the magic number is 6.6kW of solar. The reason behind this is that Energex previously only allowed a 5kW inverter on most homes, and solar regulations (through the CEC guidelines) meant that we could only install 33 percent more panels than the inverter capacity.

5kw inverter x 1.33 oversize = 6.6kW of panels

So 6.6kW solar systems were the biggest size solar system you could legally install, and it gave you best bang for buck. No wonder for several years it seemed like a one size fits all approach. But times are changing.

The new normal

Over the last year, there has been a trend in the residential solar industry to install larger systems. While 6.6kW systems remain a large proportion of our work, we regularly install 8kW, 10kW and even 15kW systems on homes. Why are systems getting bigger?

  1. As inverter technology is getting better at reacting to grid issues, Energex and other retailers are allowing larger size systems.
  2. Customers are future-proofing their solar for batteries and electric vehicles.
  3. A larger system will do a better job at covering consumption during winter and on rainy days.
  4. Increasing feed-in tariffs are making feeding power back into the grid a reasonable investment.
  5. Installing extra panels often doesn’t cost much more.

So let’s just go crazy eh?

What is the biggest solar I can install?

In South East Qld, we are limited to:

The number of phases is referring to how many lines are coming into your house. The easiest way to identify this is by the size of your main switch or by looking at your electricity meter.

  1. Most homes are single phase
  2. Only occasionally an old larger home will be 2 phase.
  3. Large homes with ducted aircon and commercial business premises are often 3 phase.

The “Export limit” column takes some explaining, Although we can put a 10kW inverter on a single phase home, we can only ever send back 5kW of power to the grid at any given time. This needs to be carefully considered in the design process with appropriate load shifting. If you want to install a Tesla battery in the future, it has a 5kW inverter for a battery charger, so you then should only install a 5kW solar inverter.

The “max panels” column is as a result of Clean Energy Council guidelines. We can only oversize the panels on the inverter by 33 percent.

As you can see, depending on the number of phases, in south-east Queensland we can install between 13 and 39kW of panels. That should be enough.

In reality, this means we are usually only really limited by your roof size and budget.

 As many panels as your roof can handle!

So you have a large roof, and batteries and/or electric cars are a likely future purchase. Let’s just go crazy and fill the roof – right?

Well, yes and no.

“Yes” because … I may-or-may-not effectively be a solar salesman (shudder).
“No”, because it’s not as simple as that.

When we design a solar system there is always a price tipping point, where getting those extra panels could cost an arm and a leg. Some examples of the parameters we have to consider are:

  1. QCell 300W panels are strung (or grouped) in a maximum string of 13. So numbers divisible by 13 are a good economical fit. 26 panels and 39 are great. 41 panels make a bad design.
  2. The price difference between a Fronius 5kW and 6kW is minimal. Then there is a bigger price step to a Fronius 7kW. If you can leave a few panels off and stick with a 6kW inverter, you’ll get better bang for your buck.
  3. With the availability of MLPE (optimisers), we can put panels on any multiple of orientations of your roof. So if you want an extra 4 panels on the only western aspect of your roof – we can do that. But MLPE comes at a cost. Sometimes it’s best to keep it simple.
  4. If a job takes my blokes 11 hours (1 day) then I need to make 1 days profit to keep the doors open. If it takes 15 hours (2 days) then I need to make double the profit margin. So if we can keep that installation simple so a strong team can install it in 1 day, your installation will be significantly more affordable.

It’s in this sense, solar is not “one size fits all”. However, rather than designing a system that will be a Goldilocks solution for your power bill,  we always try to offer one solution that will give you best bang for your buck. But if like me, you just want to go as many solar panels as you can possibly squeeze on your roof – then we can offer that solution too!

Conclusion

To size solar system to only cover your daytime usage is not only near impossible, it’s financially unsound. In recent years, many people have instead gone for what was the largest system permissible – a 6.6kW system. Now that Energex regulations have loosened up, customers are often purchasing much larger systems and feeding power back to the grid while they wait for batteries and electric vehicles to arrive. However, there is always a tipping point, and we need to consider many factors when designing a solar system that will give you best bang for buck.

Leave a Reply

Your email address will not be published. Required fields are marked

25 Comments on What size solar system do I need?

Devina Rogers said : administrator Report 3 months ago

Hi Chris, if you're in South-East Queensland, give us a call on 3268 38236 and we can arrange a remote quote or site visit. Otherwise, if you live interstate, we might be able to recommend another solar installer closer to you.

    Chris said : Guest Report 3 years ago

    Can you please quote me appropriate price for double storey home?

    • 3336
    Aztech Solar said : Guest Report 4 years ago

    Hi Mark Cavanagh, I read your article and it is very helpful for me. The way you describe different sizes of the solar panel and giving knowledge about which solar panel looks good at the rooftop. I liked that thing very much. Thanks for sharing good knowledge. Keep Sharing!!

    • 2322
    Mark C said : administrator Report 5 years ago

    Hi Dev. If you don't have shade, I would advise against using an optimizer. Read this review for why you should avoid SolarEdge.https://mcelectrical.com.au/blog/solaredge-inverter-and-optimiser-review/

      Dev said : Guest Report 5 years ago

      We have a roof which has no shade, is there a safety requirement to have optimisers or microinverters?

      • 2138
      Mark C said : administrator Report 5 years ago

      Hi Gary, We're only working in South East Qld currently. I'd suggest you get on SolarQuotes website and request 3 quotes. You should be able to find a reputable company by checking our their SolarQuotes reviews.

        Gary Evans said : Guest Report 5 years ago

        Hi Mark. Thanks for your blog. Appreciate your time to answer questions and clarify matters. Do you do any work in NSW. Am Newcastle based and we're building our home and wanting to install PV cells. Am a beginner, but learning more as i read your blogs. Thanks again

        • 2280
        Mark Cavanagh said : administrator Report 6 years ago

        Hi John. We don't do service that far north. I'd suggest call Solar Service Guys. $180 to report on it, then they will quote to fix it.

          Mark C said : administrator Report 6 years ago

          Hi Matt, At a quick look at your roofline, we could install another 4 panels, and yes, we could claim stcs on that. It shouldn't be too much of a problem to add 4 more panels. We've crunched the numbers quickly - I'll ask Ben from the office to give you a call about it.

            John Morganlowe said : Guest Report 6 years ago

            Hi Mark, thanks for the reply & info, I was informed that I couldn't replace just the on Inverter hence my search for other avenues. Before the iEnergy monitor failed I kept a pretty good check on their performance, some were a little lazy on morning startup, but most were within the 165/210 range on ideal days, but sadly no monitor now so I can only go on my daily feed in from the meter recorded since 11/16, no major time of year variation. Do any of your people get up around this way? Doonan. Is there a monitor other than iEnergy, (they don't answer emails. Taiwan) available to measure individual panels?

            • 4562
            Matt Dunleavy said : Guest Report 6 years ago

            Hi Mark, I recently had solar installed at my place from you guys. I opted to get a 6kwh inverter over a 5kwh as the price was minimal. I am now wondering whether I should have increased my panel count to match the inverter? I currently have 6.6kw (300 watt QCell). Is there much more cost in adding say 4 extra panels. (I do have the space) Can you also still get STC credits after the initial system? And I guess is the cost worth it for 4 exatra panels. Thank you in advance.

            • 4169
            Mark Cavanagh said : administrator Report 6 years ago

            Hi Adam, I haven't blogged about it. I was talking about the "residential 3 phase SolarEdge inverter". Because SolarEdge's standard 3 phase inverter operates at 750? volts, they redesigned it for the Australian residential market by effectively splitting it in half, and technically halving the voltage to bring it under 600V. The problem is, both strings (or groups of panels) have to be designed to run at equal power. So let's say you have 8 panels east, 8 west, and 4 north. We would have to take 4 panels from east, 4 from west, and 2 from the north and put them in 1 "string" of panels. Then repeat for the other string. Now let's say some of the panels are shaded. We also have to take the shading into account so it is roughly equal on both strings throughout the year. And just to keep to another annoying regulation, we have to run the cables from the strings in different conduits. Talk about increasing the cost of install!! SolarEdge seemed desperate not to lose the 3 phase residential market, but, the solution is a technical nightmare that negates the flexibility of SolarEdge in most situations.

              Mark Cavanagh said : administrator Report 6 years ago

              Hi Mark. Unfortunately not. Many inverter manufacturers are looking at the idea of a "digital compliance certificate" on up and coming models, so you can pay more and open up your 5kW inverter to be a 7kW or even a hybrid inverter. But with current inverters, that won't be possible.

                Adam Derrick said : Guest Report 6 years ago

                Hi Mark, Great read again. I am interested to hear more regarding the barriers of solar edge on Residential, as mentioned below. Have you done a blog on this in particular? Thanks mate Adam

                • 4573
                Mark C said : administrator Report 6 years ago

                Hi John, Thanks! I think you could probably replace the one micro with Enphase. But first I would monitor your system and see if it is producing what should be expected. If it is performing poorly, you might be flogging a dead horse. As mentioned in that post, STC's on a new system make up a large portion of the job. it is sometimes better just biting the bullet and replacing the whole system. Cover the roof with higher wattage panels!

                  Mark C said : administrator Report 6 years ago

                  Hi Peter. That's sounds strange. Enphase microinverters may be a good option, however, I have 15kW at my house and it runs under 600v. I've just used a 10kW and a 5kW Fronius inverter, but there would be many options. Have you been talking to someone about SolarEdge? There is an issue with their inverters on residential, but there is a workaround.

                    Mark C said : administrator Report 6 years ago

                    Hi James, It's a bit hard to draw a line, but generally, a team of 3 blokes can do 30 panels, or about 9kW in a day. If it is a Tin roof all on one orientation, and an easy switchboard, then they could do more. If it is terracotta on multiple orientations and SolarEdge, then 24 panels may be the limit. Many blokes would say that can do much more than that. I push my guys for a quality install that will last a 10-year warranty rather smashing it out quickly.

                      Mark A said : Guest Report 6 years ago

                      Hi Mark, interesting change in the rules. Can a 5KW fronius international be reprogrammed up to 6KW or even 7KW? or is it simply too late for everybody who has already installed ? I have the space to go a bit bigger. Mark A

                      • 4109
                      John said : Guest Report 6 years ago

                      Thanks Mark. Very useful info once more. Now I know why and how my neighbour has 50+ panels on the roof - Energex changed the rules !!

                      • 4152
                      John Morganlowe said : Guest Report 6 years ago

                      Great post Mark, I look forward to each new one, so much good info. After living for 35 years living off grid last year we moved to present address with an already installed 5.25kw system, schotte panels and some poorly functioning & one defunct iEnergy micro inverters, still contemplating the best way to proceed. I'm sure you're aware of the iEnery retreat from Oz so have ruled out replacing all micros. To date I've not yet obtained a quote to rewire for DC plus 4 MEPLs partial morning to early afternoon shading from early summer. We have a plug in hybrid and hope to go to full electric in 2020, also considering storage as the RIE becomes more attractive.

                      • 4562
                      Peter T said : Guest Report 6 years ago

                      Another great article Mark ... thanks! I was keen to install a 15k+ 3phase system myself as I have high consumption given that I drive a plug in hybrid. However, upon reciept and review of serval quotes and designs here in the ACT, I was stymied by the 600VDC limitation per string imposed on residential installations. Whilst I understand that this limitarion is under review, the current policy has effectively forced me back to the drawing board ... potentially having to consider microinverters as the only plausible/cost effective option. Would appreciate your take on this quandry please mate. Cheers Peter

                      • 2902
                      James said : Guest Report 6 years ago

                      Ive always wondered why there was an uptick in price per watt in larger installs, and i think you may have answered when it turns a job into a 2 day operation, and the associated margins involved with that. Generally speaking what would you say is the largest 1 day install? And hence labor sweet spot for a system? (When a home is allowed more than the std 5KW inv/6.6array)

                      • 2122
                      Mark Cavanagh said : administrator Report 6 years ago

                      Great to hear Paul! Yeh Radiant rail is leaps and bounds ahead of any other rail I've seen. I never knew there was such thing as a "non-solar person" but I'm glad you have converted! :)

                        Shirlz said : Guest Report 6 years ago

                        Another great post Mark. We have the same network limitations here in NQ. Keep up the good work selling quality, ethical solar and dispelling some of the many myths surrounding our industry. Cheers :)

                        • 4740
                        Paul Nash said : Guest Report 6 years ago

                        MCE As always sound advice Ive had my MCE slar system in for 51 weeks now and couldn't be happier I use the Fronius monitoring on the web all the time If only people would "understand" the quality of parts and material (in particular the solar panel attachment system to the roof that's made at Capalaba i think) used it would allow them to make their decision far easier . Cheapest in quoting is NOT the way to go for solar power - period Keep up the good work Great Blog and sound advice as always from MCE PS - i was always a NON SOLAR PERSON by the way (true story) Paul NASH

                        • 4109

                        Start typing and press Enter to search

                        Subscribe To Mark's Blog

                        Subscribe To Mark's Blog

                        Join our mailing list to receive the latest information, reviews and solar industry insights from MC Electrical owner Mark Cavanagh.

                        You have Successfully Subscribed!

                        Google Rating
                        4.9
                        Based on 220 reviews
                        ×
                        js_loader